I would really appreciate whatever information I can get.
We are switching over to JD Edwards Enterprise One 9.2 from a homegrown system. I have reviewed the JDE EDI Implementation Guide but I just would really like to get an idea some sample data for the 850 document for starters.
For example, for the F47011 the minimum required fields are:
EDOC - EDI document number (I know this comes from Next Number)
EDCT - EDI Document Type
EKCO - EDI Document Key Company
EDST - EDI Transaction Set
EDER - Send/Receive Flag (self explanatory)
TPUR - Transaction Set Purpose
AN8 or SHAN - Address number or Ship to Address (know what this is - but would still like to see example)
SYMCU - Business Unit (I know this is the JDE Business Unit
for example in the EDI 850 below - what would be the Document Type? What would be the Transaction Set? What would be the Send/Receive Flag?
1 ISA*00* *00* *01*001753755KRES *12*3106614111 *160126*1535*U*00401*000001152*0*P*>GS*PO*00175375
2 4111*20160126*1535*588*X*004010ST*850*0001BEG*00*N E*P211019272**20160126PER*BD*Steve Kaduk*TE*765-448-4567FOB*PPDTM
3 6TD5*****BWYMAN*PB*P211019272N9*L1*TEXTMSG*.....AL L CONDUIT MUST BE USA MADE..... ..... SHIP TO ..... KIRBY RISK 181
4 RE PKY N LAFAYETTE, IN 47904N1*BY*KIRBY RISK 1 ELECTRICAL SUPPLY*1*0017537550001N1*BT*KIRBY RISK 1 ELECTRICAL SUPPLY*1
5 1*ST*KIRBY RISK 1 ELECTRICAL SUPPLY*9*0017537550001N3*1815 SAGAMORE PKY NN4*LAFAYETTE*IN*47904PO1*000001*5000*FT*30.0
6 339202002*BP*561101***VP*E034 10FTPID*F****COND E034 EMT 3/4" 10 FTPO1*000002*3000*FT*50.82*PF***UI*78339202003*BP* 561
7 0PID*F****COND E100 EMT 1" CONDUITPO1*000003*1200*FT*119.21*PF***UI*783392020 06*BP*561109***VP*E200PID*F****COND E200
8 UITPO1*000004*2000*FT*96.00*PF***UI*98001000102*BP *560928***VP*R034PID*F****COND R034 RIGID 3/4" CONDUITCTT*4SE*25*0
9 002BEG*00*NE*P211019273**20160126PER*BD*Steve Kaduk*TE*765-448-4567FOB*PPDTM*002*20160126TD5*****BWYMAN*PB*P21101 9
10 XTMSG*.....ALL CONDUIT MUST BE USA MADE..... ..... SHIP TO ..... KIRBY RISK 835 REPPMSG*DR COLUMBUS, IN 47201N1*BY*KI
11 LECTRICAL SUPPLY*1*0017537550002N1*BT*KIRBY RISK 2 ELECTRICAL SUPPLY*1*001753755N1*ST*KIRBY RISK 2 ELECTRICAL SUPPLY*9
12 02N3*835 REPP DRN4*COLUMBUS*IN*472017475PO1*000001*5000*FT*30.00 *PF***UI*78339202002*BP*561101***VP*E034 10FTPID*F**
13 EMT 3/4" 10 FTPO1*000002*1500*FT*101.08*PF***UI*98001002005*BP *561107***VP*E112PID*F****COND E112 EMT 1-1/2" CONDUITP
14 0*FT*55.43*PF***UI*78669200001*BP*580362***VP*I012 PID*F****COND I012 IMC 1/2" CONDUITPO1*000004*2500*FT*65.60*PF***UI*
15 BP*560903***VP*I034PID*F****COND I034 IMC 3/4" CONDUITPO1*000005*250*FT*98.48*PF***UI*98001000003 *BP*560905***VP*I100
indicates non-displayable character.
Thank you
We are switching over to JD Edwards Enterprise One 9.2 from a homegrown system. I have reviewed the JDE EDI Implementation Guide but I just would really like to get an idea some sample data for the 850 document for starters.
For example, for the F47011 the minimum required fields are:
EDOC - EDI document number (I know this comes from Next Number)
EDCT - EDI Document Type
EKCO - EDI Document Key Company
EDST - EDI Transaction Set
EDER - Send/Receive Flag (self explanatory)
TPUR - Transaction Set Purpose
AN8 or SHAN - Address number or Ship to Address (know what this is - but would still like to see example)
SYMCU - Business Unit (I know this is the JDE Business Unit
for example in the EDI 850 below - what would be the Document Type? What would be the Transaction Set? What would be the Send/Receive Flag?
1 ISA*00* *00* *01*001753755KRES *12*3106614111 *160126*1535*U*00401*000001152*0*P*>GS*PO*00175375
2 4111*20160126*1535*588*X*004010ST*850*0001BEG*00*N E*P211019272**20160126PER*BD*Steve Kaduk*TE*765-448-4567FOB*PPDTM
3 6TD5*****BWYMAN*PB*P211019272N9*L1*TEXTMSG*.....AL L CONDUIT MUST BE USA MADE..... ..... SHIP TO ..... KIRBY RISK 181
4 RE PKY N LAFAYETTE, IN 47904N1*BY*KIRBY RISK 1 ELECTRICAL SUPPLY*1*0017537550001N1*BT*KIRBY RISK 1 ELECTRICAL SUPPLY*1
5 1*ST*KIRBY RISK 1 ELECTRICAL SUPPLY*9*0017537550001N3*1815 SAGAMORE PKY NN4*LAFAYETTE*IN*47904PO1*000001*5000*FT*30.0
6 339202002*BP*561101***VP*E034 10FTPID*F****COND E034 EMT 3/4" 10 FTPO1*000002*3000*FT*50.82*PF***UI*78339202003*BP* 561
7 0PID*F****COND E100 EMT 1" CONDUITPO1*000003*1200*FT*119.21*PF***UI*783392020 06*BP*561109***VP*E200PID*F****COND E200
8 UITPO1*000004*2000*FT*96.00*PF***UI*98001000102*BP *560928***VP*R034PID*F****COND R034 RIGID 3/4" CONDUITCTT*4SE*25*0
9 002BEG*00*NE*P211019273**20160126PER*BD*Steve Kaduk*TE*765-448-4567FOB*PPDTM*002*20160126TD5*****BWYMAN*PB*P21101 9
10 XTMSG*.....ALL CONDUIT MUST BE USA MADE..... ..... SHIP TO ..... KIRBY RISK 835 REPPMSG*DR COLUMBUS, IN 47201N1*BY*KI
11 LECTRICAL SUPPLY*1*0017537550002N1*BT*KIRBY RISK 2 ELECTRICAL SUPPLY*1*001753755N1*ST*KIRBY RISK 2 ELECTRICAL SUPPLY*9
12 02N3*835 REPP DRN4*COLUMBUS*IN*472017475PO1*000001*5000*FT*30.00 *PF***UI*78339202002*BP*561101***VP*E034 10FTPID*F**
13 EMT 3/4" 10 FTPO1*000002*1500*FT*101.08*PF***UI*98001002005*BP *561107***VP*E112PID*F****COND E112 EMT 1-1/2" CONDUITP
14 0*FT*55.43*PF***UI*78669200001*BP*580362***VP*I012 PID*F****COND I012 IMC 1/2" CONDUITPO1*000004*2500*FT*65.60*PF***UI*
15 BP*560903***VP*I034PID*F****COND I034 IMC 3/4" CONDUITPO1*000005*250*FT*98.48*PF***UI*98001000003 *BP*560905***VP*I100
indicates non-displayable character.
Thank you
from JDELIST - JD Edwards® EnterpriseOne Technical http://ift.tt/1SkqjMU
via IFTTT
Did you ever find out what the EDI doc type should be? We want to start accepting inbound 850s and I'm not sure what EDCT should be.
ReplyDelete